WEG CSW-BD21SS WH PUSHBUTTON CSW-BD21SS-WH ACCESSORIES THERMAL OVERLOAD RELAYS - RWDeveloped for harsh environments and industrial applications, WEG line of Push Buttons and Pilot Lights employs high technology in the project and manufacturing, offering a modern and ergonomic design. Front type Double Actuation form Pulsator Front color Green Red Actuation signaling Not contain Front coating Uncoated Specific function START STOP (SS) Attributes Front type Double Actuation form Pulsator Front color Green Red Actuation signaling Not
WEG enclosed starters series were designed to meet the requirements and flexibility frequently demanded in industrial applications
Standard NEMA MG-1 Frequency 60//50 Hz Voltage 230/460//190-220/380-415 V Number of poles 4 Synchronous speed 1800 rpm Output rating 2 HP Mounting W-6 Flange C Terminal box¹ Left position Enclosure IC01 - ODP
Series EXWX-M Panel type Across the line Horsepower (HP) 25 HP Enclosure type Wall mount Thermal Managment None General enclosure options None Main voltage 575 V Control Voltage Not applicable Frequency 60 Hz SCCR rating 25 kAIC Disconnect switch type Circuit Breaker rotary handle disconnect Bypass type None Control power transformer No transformer required Reactor/Filter None Communication None Control options None Enclosure rating Type 7/9 Nominal height 285
375 MOUNTING BRACKET/STUD MOTOR TYPE FHP OPPOSITE END BEARING SELF-ALIGN SHAFT END BEARING SELF-ALIGN ROTATION CCW LEAD END REV SERVICE FACTOR 1 RUNCAPMFD 7
3 s Control voltage 100-240V 50/60Hz-DC Color Blue Attributes
Reference RW67 Number of poles 3 poles Mounting type Direct Contactor model CWB40-80 Current range 25-40 A Attributes
0 kVAr Application Power Factor Correction Type Fixed Rated current 4
15 STARTCAPMFD N\A SHIPPING WEIGHT 950 BREAKDOWN TORQUE 218 BREAKDOWN TORQUE UOM PERCENT OF FLT LOCKED ROTOR TORQUE 154 LOCKED ROTOR TORQUE UOM PERCENT OF FLT INSULATION CLASS F KVA CODE LETTER E LOCKED ROTOR AMPS 341 NEMA NOMINAL EFFICIENCY 94
15 STARTCAPMFD N\A SHIPPING WEIGHT 55 BREAKDOWN TORQUE 438 BREAKDOWN TORQUE UOM PERCENT OF FLT LOCKED ROTOR TORQUE 347 LOCKED ROTOR TORQUE UOM PERCENT OF FLT INSULATION CLASS F KVA CODE LETTER L LOCKED ROTOR AMPS 36 NEMA NOMINAL EFFICIENCY 87
15 STARTCAPMFD N\A SHIPPING WEIGHT 188 BREAKDOWN TORQUE 234 BREAKDOWN TORQUE UOM PERCENT OF FLT LOCKED ROTOR TORQUE 155 LOCKED ROTOR TORQUE UOM PERCENT OF FLT INSULATION CLASS F KVA CODE LETTER G LOCKED ROTOR AMPS 53
2x(Code H) No load current 37
32 BREAKDOWN TORQUE UOM OZFT LOCKED ROTOR TORQUE 24